SI MIP6 C ( MIP 6 )

SI-MIP6

Motor Insulation Protection
(MIP-6)
SI MIP6 C ( MIP 6 )
Rated Supply Voltage
110V – 230V
Download brochure Download

Sophisticated Off-Line Motor Insulation measure and Protection unit for Motors up to 15kV
The SI-MIP6 is a fully digital unit and can be used for all types of AC motors. Designed for testing the insulation resistance of both Low Voltage and Medium Voltage motors, with two types of Minimum and Maximum insulation resistance levels are recorded.
One type is for the present month and the other for minimum and maximum levels since the last reset. A built-in programmable time delay prevents a mistaken insulation measurement due to motor cable capacitances and motor induced voltages.
Using automatically adjustable DC voltage level for the optimal Insulation resistance measurement our Motor Insulation System protects the system from abnormal low insulation resistance conditions in the motor and cabling. At a time when a fault is detected, the SI-MIP6 system will alarm or trip the motor or prevent starting.

Advantages

  • Actual insulation resistance.
  • Last twenty-four hours average insulation resistance.
  • Previous month average insulation resistance.
  • Previous year average insulation resistance

Features

  • Monitors insulation deterioration of Medium Voltage motors
  • Displays the present and average insulation resistance on LCD
  • Monitoring while motors are de-energized
  • Programmable parameters Microprocessor based technology
  • Alarm / Trip Setpoint in the range of 0.1 to 60 Mega Ohms
  • Utilizes up to 48 VDC test voltage to increase personnel safety
  • Illuminated LCD display with 2 lines of 16 characters each
  • Six keys for easy programming
  • Three LEDs for easy status indication
  • Deterioration monitoring by storing history with time stamp
  • Unauthorized parameter modification prevention
  • Four C/O 8 Amp., 250V programmable signalling relays
  • Analog 0/4-20mA output for remote reading
  • Modbus communication
  • Control Voltage: 85-230VDC/AC (50/60Hz)
  • Operating Temperature Range 0°C to +50°C (default – all units) -10°C to +60°C (optional)

Options

  • Analog output
  • Conformal coating
  • Modbus

Applications

Process
Mining
Oil & Gas
Marine
Water
Hvac
Ball Mill
Compressor
Conveyor
Debarker
Fan
Hydraulic Power Pack
Hydraulic Pump
Mixer
Pump
Agitator
Ball Mill
Compressor
Conveyor
Debarker
Excavator
Fan
Hammer mill
Hydraulic Power Pack
Pump
Rock Crusher
Water Pump
Compressor
Fan
Injection Pump
Pump
Chiller
Hydraulic Pump
Propulsion Motor
Pump
Thruster
Water Pump
Pump
Sewege Pump
Water Pump
Chiller
Compressor
Fan
Pump