Empowering Industries - Industrial Motor Protection Systems
Revealing the Key Benefits of SOLCON-IGEL’s Motor System & Protection Products
By Wassim Mousa
Introduction
In the examination of motor protection, it is essential to take into account that, during the initial phase, the machine draws a current approximately six times its rated value for a variable duration. This duration is dependent on the specific characteristics of the driven machine. In the case of a network short-circuit, the motor exhibits behavior akin to that of a generator in the initial moments. It supplies the fault with a current theoretically equivalent to the starting current. Both the startup conditions and the motor’s contribution to the short-circuit are significant operational scenarios. Therefore, the design of protection measures is crucial to prevent false trips under these circumstances.
Motor faults or abnormal operating conditions can be categorized and identified.
Motor Protection
The protection must be capable of recognizing the following issues:
Overload
Short-circuit
Ground fault
Prolonged starting
Locked rotor during running
Unbalanced load
Excessive number of starts
Different protection functions can detect these operating conditions, functioning as backups for one another. For example, the identification of short circuits may involve the use of overcurrent protections and/or differential protections.
Essential protection functions recommended for a motor are as follows:
ANSI 49: Thermal protection against overload
ANSI 50: Overcurrent short-circuit protection (which may be in association with fuses)
ANSI 87M: Differential protection
ANSI 51G: Overcurrent ground fault protection
ANSI 48: Overcurrent protection against prolonged starting
ANSI 51LR: Overcurrent protection against locked rotor during running
ANSI 46: Negative sequence overcurrent protection
ANSI 66: Number of starts control protection.
ANSI 27: Under voltage protection against motor disconnection
ANSI 37: Undercurrent protection (typical for submerged pumps)
ANSI 78: Protection against out-of-step for synchronous motors
Figure 1 – Solcon-IGEL Soft-Starter System
The provided image highlights the diverse range of protection solutions provided by Solcon-IGEL for various applications, designed to meet the specific requirements of clients.
The figure presents a variety of protection system configurations providing flexibility in selection based on factors such as machine power, connection unit, and neutral status.
Solcon-IGEL’s comprehensive range of protections underscores their commitment to delivering customized and effective solutions tailored to address the unique needs of their clientele across various applications.
Viewing the motor as a user terminal within the electric system, the protection system setting operates independently of other network protections. Differential protection holds particular significance for motors, especially in scenarios where short-circuit currents are low. This offers the advantage of faster trip times compared to standard overcurrent protection. However, implementing differential protection for motors can pose as a challenge, making the inclusion of star point side CTs necessary. At times, special versions may be required for the motor terminal box, or external cabinets may be needed for CT installation and star point formation.
ANSI 49 Thermal Overload Protection
The thermal overload protection element, mimicking the motor’s time constant, guarantees effective motor protection in cases of overload. In accordance with the thermal relay standard, the protection’s trip curve exhibits an exponential pattern.
In the protection setting process, particularly when the motor is designed for ‘HOT’ restarting, it becomes crucial to verify that the equivalent thermal curve allows the passage of the starting current for the necessary duration. In the thermal protection domain, it is standard practice to configure both the heating time constant and the cooling time constant to ensure optimal performance and effectively safeguard the motor.
(See my previous article “Optimizing Motor Protection: The Advantages of Coordination Tool for Thermal Element Setting in SEL-710 Relays“)
Balanced three-phase loads generate a synchronous rotating field in the stator that aligns with the rotor. However, in the presence of unbalanced loads, the negative sequence component in the stator current induces a rotor current with twice the frequency of the rated one. This induced current, flowing through the rotor winding, results in significant heating in the rotor.
This protection function is crucial for safeguarding the motor in scenarios involving one or two missing phases in the power supply, as well as for addressing unbalanced currents of minor amplitude. The protection mechanism is designed to activate over extended durations for small transient currents. Given its primary objective of preventing excessive heating in the rotor circuit, this protection feature necessitates a well-defined time characteristic.
ANSI 50 Overcurrent Protection
This protective function is dedicated to safeguarding the motor, especially when connected with a relative connection cable, from critical phase-to-phase or three-phase faults. In situations where outgoing feeders are equipped with both a contactor and a fuse, the short-circuit protection depends on the fuse. However, it is crucial to integrate short-circuit overcurrent protection to identify smaller faults that can be resolved by interrupting the contactor
In situations where a contactor and fuse are involved, the protection mechanism necessitates a delay to coordinate effectively with the opening characteristics of the contactor and the trip curve of the fuse. Conversely, when an outgoing feeder is equipped with a circuit-breaker, a delay in the trip time is invariably introduced to accommodate the passage of peak currents during motor starting. This meticulous approach ensures comprehensive protection against various fault scenarios in the motor system.
ANSI 51G/67G Ground Fault Overcurrent Protection
This functions as a homopolar overcurrent protection specifically designed to handle ground faults, with a crucial consideration being the evaluation of the necessity for directionality. Remarkably, directional protection is essential when the capacitive contribution of the motor and its associated cable surpasses the predefined threshold.
As a result, this protection mechanism operates as the initial stage of selectivity for detecting and addressing ground faults, emphasizing its pivotal role in the overall protective strategy for the motor system.
ANSI 48 Maximum Start Time
This protection function is exclusively activated during the motor’s startup phase, becoming inactive once the designated startup time elapses. Its primary objective is to verify that the motor initiates within the predetermined time frame. Exceeding the calculated starting time can result in overheating of the windings, posing a significant risk to the machine’s lifespan.
In the selection of the protection system for machines and plants, a crucial parameter for configuring this protection is the starting time. This parameter is intricately linked to the operational characteristics of the machine connected to the axle, underscoring the need for a tailored and precise approach in defining the protection settings.
ANSI 51LR Locked Rotor Overcurrent Protection
This protective function remains inactive during the initial starting phase and is engaged only after the startup process ends. It serves to inspect abnormal operating conditions in the motor resulting from a lock, often attributed to issues such as bearing failure or stall conditions.
ANSI 27 Under-Voltage Protection
An under-voltage relay employed for motor protection serves various purposes in different applications:
To prevent voltage drops in the network from reaching critical levels, which could potentially lead to motor stall conditions.
To confirm that the voltage is sufficiently high when a circuit breaker closes, ensuring proper conditions for motor startup.
To disconnect the motor in the absence of voltage in the network, preventing simultaneous restarts with other machines and the subsequent risk of network collapse.
The settings and operational commands of the protection mechanism vary based on the specific function it is intended to fulfill, highlighting the adaptability of under-voltage relays in addressing diverse motor protection requirements.
ANSI 87M Differential Protection
Differential motor protection employs two distinct techniques:
Compensated Differential Protection: This method employs a set of three line-side and three star-point-side current transformers (CTs). A challenge with this approach arises from the significant performance demand placed on the CT on the star-point side, which must effectively supply the connection cable between the CT and the relay, considering the distance between the switchgear and the motor.
Self-Balancing Protection: This alternative utilizes only one set of three star-point-side CTs. Each CT, covering a phase of the motor, measures the vectorial sum of the incoming and outgoing currents. Any non-zero value indicates a fault within the machine.
This protection function, operating as a simple overcurrent relay with an instantaneous threshold, offers the advantage of allowing the CT for differential protection to have a much lower rated primary current than the motor’s rated current. This characteristic enhances the sensitivity of the protection, surpassing even that of the traditional differential protection method.
Conclusion
The detailed exploration of motor protection considerations, as well as the extensive array of solutions presented by Solcon-IGEL, underscores the company’s commitment to innovation and client-centric solutions.
By addressing crucial aspects such as overload, short-circuit, ground fault, and various abnormal operating conditions, Solcon-IGEL demonstrates a thorough understanding of the diverse challenges faced by different applications and offer cutting-edge technology.
In essence, this article not only serves as a comprehensive guide to motor protection considerations but also highlights Solcon-IGEL position as a leading provider motor solutions and client-specific protection solutions in a diverse industrial applications.
Our commitment to addressing the unique needs of our clients positions us as a reliable partner in ensuring the optimal performance and longevity of motor systems across diverse sectors.
Contact Us
For any questions and further information
Solcon-IGEL is a developer and manufacturer of soft starters, heat control systems, and motor control and protection solutions for heavy industry. Our power electronic technologies are engineered for reliable operation across a wide range of industrial motor applications worldwide.
Our website uses cookies, by clicking “Accept All” you are helping us optimise your experience. If you wish to change these settings, you can do so by clicking on “Cookie Settings”. Read More
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. These cookies ensure basic functionalities and security features of the website, anonymously.
Cookie
Duration
Description
cookielawinfo-checkbox-advertisement
1 year
Set by the GDPR Cookie Consent plugin, this cookie is used to record the user consent for the cookies in the "Advertisement" category .
cookielawinfo-checkbox-analytics
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics".
cookielawinfo-checkbox-functional
11 months
The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional".
cookielawinfo-checkbox-necessary
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-others
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other.
cookielawinfo-checkbox-performance
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance".
CookieLawInfoConsent
1 year
Records the default button state of the corresponding category & the status of CCPA. It works only in coordination with the primary cookie.
viewed_cookie_policy
11 months
The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
Cookie
Duration
Description
pll_language
1 year
The pll _language cookie is used by Polylang to remember the language selected by the user when returning to the website, and also to get the language information when not available in another way.
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.
Cookie
Duration
Description
_ga
2 years
The _ga cookie, installed by Google Analytics, calculates visitor, session and campaign data and also keeps track of site usage for the site's analytics report. The cookie stores information anonymously and assigns a randomly generated number to recognize unique visitors.
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.